Existing pump - Circulation
                    Replacement pump - High Efficiency Standard Exchange sheet
                    Comment
                Product information
                
                Yonos PICO-D 30/1-6
                
            
        
                                                                    Your advantages
- LED display for adjusting the setpoint in 0.1 m increments and showing effective consumption
 - Electrical connection without tools using the Wilo-Connector
 - Unique pump venting function per pump
 - Twin-head pump for individual (Δp-c, Δp-v and constant speed) or parallel (Δp-c and constant speed) operation
 - Very high starting torque for reliable starting
 
Glandless twin-head circulator with screwed connection, blocking-current proof EC motor and integrated electronic power control.
Application
All hot-water heating systems, air-conditioning applications, industrial circulation systems.
Equipment/function
Operating modes:
- Constant differential pressure
 - Variable differential pressure
 - Constant speed (3 control pump curves)
 
- Setting the operating mode in accordance with the application
 - Setting of pump output (delivery head)
 - Setting the constant speed
 - Pump venting function
 - Manual restart
 
- Continuous power adjustment according to the operating mode
 - Automatic restart
 - Automatic dry-running detection
 
- Display of power consumption in W
 - Display of delivery head for setting
 - Display of fault messages (error codes)
 - Display of manually activated restart or pump venting function
 
- Quick electrical connection with Wilo-Connector
 - Pump venting function
 - Manual restart
 - Blocking-current proof motor
 - Particle filter
 
- Main/standby mode (automatic fault-actuated switchover/time-dependent pump cycling). If the twin-head pump is to be operated in main/standby operation, the control mode and the delivery head or speed stage C1, C2, C3 must be set so they are identical.
 - Parallel operation (efficiency-optimised peak-load activation and deactivation). If the twin-head pump is to be operated in parallel/peak-load operation, the control mode Δp-c must be set with the same delivery head or constant speed with identical speed stage C1, C2, C3.
 - An additional switchgear is required for switching the pumps, e.g. in the event of a fault.
 
- Pump
 - Wilo-Connector
 - Gaskets
 - Installation and operating instructions
 
- Fluid temperature -10 °C to +95 °C
 - Mains connection 1~230 V, 50 Hz
 - Protection class IPX2D
 - Rp 1¼ screwed connection
 - Max. operating pressure 10 bar