1 replacement option found

Existing pump - Circulation

Brand Salmson
Product name DIL 205-14/3
Overall length 340 mm
Mains connection 3x400 V
Pipe Connection DN 50 PN16

Replacement pump - Conventional Exchange sheet

Product name DL 50/140-3/2
Item no. 2121025
MEI ≥ 0,4
IE 3
Overall length 340 mm
Mains connection 3x400 V
Pipe Connection DN 50 PN16
Rated Current 5,8 A
Fluid temperature range -20 - +140 °C

Comment

Fits without any modification of piping.

Product information
DL 50/140-3/2

DL 50/140-3/2
Item no. : 2121025

Your advantages
  • Reduced life cycle costs through optimised efficiency
  • Can be used flexibly in air-conditioning and cooling systems, with application benefits due to direct draining of condensate via optimised lantern design (patented)
  • High standard of corrosion protection thanks to cataphoretic coating
  • Main/standby mode or peak-load operation (by means of external auxiliary device)
Construction
Glanded twin-head pump in in-line design with flange connection.

Application
Pumping of heating water (acc. to VDI 2035), cold water and water/glycol mixtures without abrasive substances in heating, cold water and cooling systems.

Scope of delivery
  • Pump
  • Installation and operating instructions
Technical data
  • Permissible temperature range -20 °C to +140 °C
  • Mains connection 3~400 V, 50 Hz (others on request)
  • Protection class IP 55
  • Nominal diameter DN 32 to DN 200
  • Max. operating pressure 16 bar
Materials
  • Pump housing and lantern: Standard: EN-GJL-250
  • Impeller: Standard: EN-GJL-200; special version: Bronze CuSn 10
  • Shaft: 1.4122
  • Mechanical seal: AQEGG; other mechanical seals on request
Description/construction
Single-stage, low-pressure twin-head pump in in-line design with: 
  • Switchover valve
  • Mechanical seal
  • Flange connection with pressure measuring connection R 1/8
  • Lantern
  • Coupling
  • IEC standard motor
COUNTER FLANGE KIT DN50 PN10
Item no.: 2105581
Mating flanges:
  • Made of steel.
  • Counter flanges (weld) are delivered complete (in pairs) with bolt, nut and flange gasket.
BLIND-FLANGE P190 KIT
Item no.: 2040970
Blinds for service and repair work.
  • Comes in a complete kit containing a lid and gasket.
Flange gasket DN 50 PN6/10
Item no.: 2150974
Flange gasket DN 50 PN6 / 10, Klingersil:
  • Thickness: 2 mm.
  • Inner diameter: 61 mm.
  • Outer diameter: 96 mm.
Difference pressure sensor 10 m
Item no.: 2136454

The differential pressure sensor kit enables dp-c and dp-v control of the frequency-controlled high-pressure centrifugal pumps.
The sensor measures the differential pressure between the suction ports and discharge ports to the pipes, and converts this into an electrical signal 4-20 mA, which is used by the frequency converter to regulate the pressure of the pump. The value of the output current is proportional to the differential pressure.
Difference pressure sensor 20 m
Item no.: 2136456

The differential pressure sensor kit enables dp-c and dp-v control of the frequency-controlled high-pressure centrifugal pumps.
The sensor measures the differential pressure between the suction ports and discharge ports to the pipes, and converts this into an electrical signal 4-20 mA, which is used by the frequency converter to regulate the pressure of the pump. The value of the output current is proportional to the differential pressure.
Difference pressure sensor 40 m
Item no.: 2136458

The differential pressure sensor kit enables dp-c and dp-v control of the frequency-controlled high-pressure centrifugal pumps.
The sensor measures the differential pressure between the suction ports and discharge ports to the pipes, and converts this into an electrical signal 4-20 mA, which is used by the frequency converter to regulate the pressure of the pump. The value of the output current is proportional to the differential pressure.
Difference pressure sensor 60 m
Item no.: 503184696

The differential pressure sensor kit enables dp-c and dp-v control of the frequency-controlled high-pressure centrifugal pumps.
The sensor measures the differential pressure between the suction ports and discharge ports to the pipes, and converts this into an electrical signal 4-20 mA, which is used by the frequency converter to regulate the pressure of the pump. The value of the output current is proportional to the differential pressure.
Difference pressure sensor 100 m
Item no.: 503184799

The differential pressure sensor kit enables dp-c and dp-v control of the frequency-controlled high-pressure centrifugal pumps.
The sensor measures the differential pressure between the suction ports and discharge ports to the pipes, and converts this into an electrical signal 4-20 mA, which is used by the frequency converter to regulate the pressure of the pump. The value of the output current is proportional to the differential pressure.
Frequency converter EFC 3,0 kW 3~
Item no.: 2551150