Existing pump - Circulation
                    Replacement pump - Electronic Exchange sheet
Comment
                Product information
                
                IL-E 100/150-15/2
                
            
        
                                                                    Your advantages
- Energy savings due to integrated electronic power adjustment
 - Optional interfaces for bus communication using plug-in IF-Modules
 - Simple operation with Green Button Technology and display
 - Integrated dual pump management
 - Integrated full motor protection (PTC thermistor sensor) with trip electronics
 
Electronically controlled glanded single pump in in-line design with flange connection and automatic power adjustment.
Application
Pumping of heating water (acc. to VDI 2035), cold water and water/glycol mixtures without abrasive substances in heating, cold water and cooling systems.
Equipment/function
Operating modes:
- Δp-c for constant differential pressure
 - Δp-v for variable differential pressure
 - PID control
 - Constant speed (n=constant)
 
- Green button and display
 
- Differential pressure setpoint setting
 - Setting the speed (manual control mode)
 - Setting the operating mode
 - Setting the pump ON/OFF
 - Configuration of all operating parameters
 - Fault acknowledgement
 
- "Overriding Off" control input
 - “External pump cycling” control input (effective only in dual pump operation)
 - Analogue input 0 – 10 V, 0 – 20 mA for constant speed (DDC) and remote setpoint adjustment
 - Analogue input 2 – 10 V, 4 – 20 mA for constant speed (DDC) and remote setpoint adjustment
 - Analogue input 0 – 10 V for actual value signal from pressure sensor
 - Analogue input 2 – 10 V, 0 – 20 mA, 4 – 20 mA for actual value signal from pressure sensor
 
- Collective fault signal SSM
 - Collective run signal SBM
 
- Infrared interface for wireless data exchange with IR-Monitor/IR-Stick
 - Plug-in position for Wilo IF-Modules (Modbus, BACnet, CAN, PLR, LON) for connection to building automation
 
- Full motor protection with integrated trip electronics
 - Access disable
 
- Main/standby operation (automatic fault-actuated switchover)
 - Pump cycling main/standby operation after 24 hours
 - Parallel operation
 - Parallel operation (efficiency-optimised peak-load activation and deactivation)
 
- Pump
 - Installation and operating instructions
 
- Permissible temperature range of -20 °C to +140 °C
 - Mains connection
 - 3~440 V ±10 %, 50/60 Hz
 - 3~400 V ±10 %, 50/60 Hz
 - 3~380 V -5 % +10 %, 50/60 Hz
 - Protection class IP 55
 - Nominal diameter DN 40 to DN 200
 - Max. operating pressure 16 bar up to +120 °C, 13 bar up to +140 °C
 
- Pump housing and lantern: EN-GJL-250
 - Impeller
 - Standard version: EN-GJL-200
 - Special version: Bronze CuSn 10
 - Shaft: 1.4122
 - Mechanical seal: AQEGG; other mechanical seals on request
 
Single-stage, low-pressure centrifugal pump in in-line design with:
- Mechanical seal
 - Flange connection
 - Lantern
 - Coupling
 - Drive with integrated electronic speed control
 
                                                            - Made of steel.
 - Counter flanges (weld) are delivered complete (in pairs) with bolt, nut and flange gasket.
 
                                                            - Thickness: 2 mm.
 - Inner diameter: 115 mm.
 - Outer diameter: 152 mm.