Existing pump - Circulation
                    Replacement pump - Conventional Exchange sheet
Comment
                Product information
                
                IPL 25/80-0,12/2
                
            
        
                                                                    Your advantages
- High standard of corrosion protection thanks to cataphoretic coating
 - Standard condensate drainage holes in the motor housings and lanterns
 - Series design: motor with one-piece shaft
 - Version N: Standard motor V1 with stainless steel plug shaft
 - Bidirectional, force-flushed mechanical seal
 
Glanded pump in in-line design with screwed connection or flange connection.
Application
Pumping of heating water (acc. to VDI 2035), cold water and water/glycol mixtures without abrasive substances in heating, cold water and cooling systems.
Scope of delivery
- Pump
 - Installation and operating instructions
 
- Permissible temperature range -20 °C to +120 °C
 - Mains connection 3~400 V, 50 Hz (others on request)
 - Protection class IP 55
 - Nominal diameter Rp 1 to DN 100
 - Max. operating pressure 10 bar (special version: 16 bar)
 
- Pump housing and lantern: EN-GJL-250
 - Impeller: PPO fibreglass-reinforced EN-GJL-200 (depending on pump type)
 - Shaft: 1.4021
 - Mechanical seal: AQEGG; other mechanical seals on request
 
Single-stage, low-pressure centrifugal pump in in-line design with:
- Mechanical seal
 - Flange connection with pressure measuring connection R 1/8
 - Motor with one-piece shaft
 
                                                            
                                                            Automatic reactivation of pump after power failure and automatic fault acknowledgement after cooling off of the motor.
Equipment/function:
- Full motor protection tripping unit for pumps with thermal winding contact (WSK)
 - Switch on/off with integrated run signal light
 - Terminals for external, potential-free activation/deactivation
 - Connection terminal strip
 
                                                            Automatic reactivation of pump after power failure and automatic fault acknowledgement after cooling off of the motor.
Equipment/function:
- Full motor protection tripping unit for pumps with thermal winding contact (WSK)
 - Switch on/off with integrated run signal light
 - Fault signal light
 - Terminals for external, potential-free activation/deactivation
 - Potential-free contacts for external run signal (SBM) and fault signal (SSM)
 - Connection terminal strip
 
- Switchgear SK 622N
 - 4 threaded cable connections M20
 - Installation and operating instructions