1 replacement option found

Existing pump - Circulation

Brand Salmson
Product name LRL 406-12/0,37
Overall length 340 mm
Mains connection 3x400 V
Pipe Connection DN 65 PN10

Replacement pump - Conventional Exchange sheet

Product name IPL 65/120-0,37/4
Item no. 2129204
MEI ≥ 0,4
IE 2
Overall length 340 mm
Mains connection 3x400 V
Pipe Connection DN 65 PN10
Rated Current 0,96 A
Nominal power P2 0,37 kW
Fluid temperature range -20 - +120 °C

Comment

Fits without any modification of piping.

Product information
IPL 65/120-0,37/4

IPL 65/120-0,37/4
Item no. : 2129204

Your advantages
  • High standard of corrosion protection thanks to cataphoretic coating
  • Standard condensate drainage holes in the motor housings and lanterns
  • Series design: motor with one-piece shaft
  • Version N: Standard motor V1 with stainless steel plug shaft
  • Bidirectional, force-flushed mechanical seal
Construction
Glanded pump in in-line design with screwed connection or flange connection.

Application
Pumping of heating water (acc. to VDI 2035), cold water and water/glycol mixtures without abrasive substances in heating, cold water and cooling systems.

Scope of delivery
  • Pump
  • Installation and operating instructions
Technical data
  • Permissible temperature range -20 °C to +120 °C
  • Mains connection 3~400 V, 50 Hz (others on request)
  • Protection class IP 55
  • Nominal diameter Rp 1 to DN 100
  • Max. operating pressure 10 bar (special version: 16 bar)
Materials
  • Pump housing and lantern: EN-GJL-250
  • Impeller: PPO fibreglass-reinforced EN-GJL-200 (depending on pump type)
  • Shaft: 1.4021
  • Mechanical seal: AQEGG; other mechanical seals on request
Description/construction
Single-stage, low-pressure centrifugal pump in in-line design with: 
  • Mechanical seal
  • Flange connection with pressure measuring connection R 1/8
  • Motor with one-piece shaft
COUNTER FLANGE KIT DN65 PN10
Item no.: 2105583
Mating flanges:
  • Made of steel.
  • Counter flanges (weld) are delivered complete (in pairs) with bolt, nut and flange gasket.
Flange gasket DN 65 PN6/10
Item no.: 2151002
Flange gasket DN 65 PN6 / 10, Klingersil:
  • Thickness: 2 mm.
  • Inner diameter: 77 mm.
  • Outer diameter: 115 mm.
SWITCH BOX SK602N
Item no.: 2120444
Wall-mounted unit for electrical connection of single-phase and three-phase pumps with integrated thermal winding contacts (WSK) for monitoring the winding temperature (full motor protection).
Automatic reactivation of pump after power failure and automatic fault acknowledgement after cooling off of the motor.

Equipment/function:
  • Full motor protection tripping unit for pumps with thermal winding contact (WSK)
  • Switch on/off with integrated run signal light
  • Terminals for external, potential-free activation/deactivation
  • Connection terminal strip
SWITCH BOX SK622N
Item no.: 2120445
Wall-mounted unit for electrical connection of single-phase and three-phase pumps with integrated thermal winding contacts (WSK) for monitoring the winding temperature (full motor protection) and external run/fault signal.
Automatic reactivation of pump after power failure and automatic fault acknowledgement after cooling off of the motor.

Equipment/function:
  • Full motor protection tripping unit for pumps with thermal winding contact (WSK)
  • Switch on/off with integrated run signal light
  • Fault signal light
  • Terminals for external, potential-free activation/deactivation
  • Potential-free contacts for external run signal (SBM) and fault signal (SSM)
  • Connection terminal strip
Scope of delivery:
  • Switchgear SK 622N
  • 4 threaded cable connections M20
  • Installation and operating instructions
Frequency converter EFC-0,37 kW 3~
Item no.: 2550224
Difference pressure sensor 10 m
Item no.: 2136454

The differential pressure sensor kit enables dp-c and dp-v control of the frequency-controlled high-pressure centrifugal pumps.
The sensor measures the differential pressure between the suction ports and discharge ports to the pipes, and converts this into an electrical signal 4-20 mA, which is used by the frequency converter to regulate the pressure of the pump. The value of the output current is proportional to the differential pressure.
Difference pressure sensor 20 m
Item no.: 2136456

The differential pressure sensor kit enables dp-c and dp-v control of the frequency-controlled high-pressure centrifugal pumps.
The sensor measures the differential pressure between the suction ports and discharge ports to the pipes, and converts this into an electrical signal 4-20 mA, which is used by the frequency converter to regulate the pressure of the pump. The value of the output current is proportional to the differential pressure.
Difference pressure sensor 40 m
Item no.: 2136458

The differential pressure sensor kit enables dp-c and dp-v control of the frequency-controlled high-pressure centrifugal pumps.
The sensor measures the differential pressure between the suction ports and discharge ports to the pipes, and converts this into an electrical signal 4-20 mA, which is used by the frequency converter to regulate the pressure of the pump. The value of the output current is proportional to the differential pressure.
Difference pressure sensor 60 m
Item no.: 503184696

The differential pressure sensor kit enables dp-c and dp-v control of the frequency-controlled high-pressure centrifugal pumps.
The sensor measures the differential pressure between the suction ports and discharge ports to the pipes, and converts this into an electrical signal 4-20 mA, which is used by the frequency converter to regulate the pressure of the pump. The value of the output current is proportional to the differential pressure.
Difference pressure sensor 100 m
Item no.: 503184799

The differential pressure sensor kit enables dp-c and dp-v control of the frequency-controlled high-pressure centrifugal pumps.
The sensor measures the differential pressure between the suction ports and discharge ports to the pipes, and converts this into an electrical signal 4-20 mA, which is used by the frequency converter to regulate the pressure of the pump. The value of the output current is proportional to the differential pressure.