Stratos MAXO 30/0,5-6
Your advantages
- Intuitive operation by means of application-guided settings with the Setup Guide plus the combination of a new display and operating button using Green Button Technology.
- Maximum energy efficiency thanks to the combination of optimised and innovative energy-saving functions (e.g. No-Flow Stop).
- Optimum system efficiency thanks to new and innovative intelligent control functions, such as Dynamic Adapt plus, Multi-Flow Adaptation, T-const. and ΔT-const.
- Latest communication interfaces (e.g. Bluetooth) for connection to mobile devices and direct pump networking for multiple pump control via Wilo Net.
- Maximum convenience in electrical installation thanks to a clearly arranged and spacious terminal room and the optimised Wilo-Connector.
With optimised and innovative energy-saving features, the Wilo-Stratos MAXO sets new standards for commercial HVAC and drinking water applications in terms of energy efficiency. Its outstanding user-friendliness makes operating the pump easier than ever before.
Construction
Smart glandless circulator with screwed connection or flange connection, EC motor with integrated electronic power adjustment.
Application
Hot-water heating systems of all kinds, air-conditioning systems, closed cooling circuits, industrial circulation systems.
Equipment/function
Field of application
The pump facilitates an operation with highest system efficiency via precise setting of the control mode for the system-specific application (e.g. radiator, underfloor heating, ceiling cooling).
Heating:
- Radiator
- Underfloor heating
- Ceiling heating
- Fan heater
- Hydraulic shunt
- Heat exchanger
- Ceiling cooling
- Underfloor cooling
- Air-conditioning devices
- Hydraulic shunt
- Heat exchanger
- Automatic switchover
Control modes
- Constant speed (control mode)
- Δp-c for constant differential pressure
- Δp-v for variable differential pressure
- Dynamic Adapt plus for continuous (dynamic) adjustment of the delivery rate to the current requirement
- T-const. for constant temperature regulation
- ΔT for differential temperature control
- Constant Q for constant volume flow control
- Multi-Flow Adaptation: Total volume flow determination through the feeder pump for the needs-based supply of secondary pumps in the heating circuit distributors
- User-defined PID controller
- Q-limitmax. for limiting the maximum volume flow
- Q-limitmin. for limiting the minimum volume flow
- No-Flow Stop (zero-flow-deactivation)
- Automatic setback operation
- Index circuit evaluator (Δp-c control with external actual value sensor)
- Variable pitch of Δp-v pump curve
- Selection of the field of application using the Setup Guide
- Setting the related operating parameters
- Nominal duty point: direct input of calculated duty point at Δp-v
- Status display
- Setting and resetting the energy meters (heating and cooling)
- Pump venting function
- Key lock for disabling the settings
- Function for resetting the factory settings or the saved restoration points (parameter sets)
- Parameterising the analogue inputs
- Parameterising the binary inputs
- Parameterising the relay outputs
- Dual pump function (for 2 single pumps, which should be operated as twin-head pump)
- Power adjustment according to requirements for energy-efficient operation depending on the operating mode
- Setback operation
- Deactivation at zero flow (No-Flow Stop)
- Soft start
- Automatic troubleshooting routines (e.g. deblocking function)
- Switchover heating/cooling mode
- Full motor protection with integrated trip electronics
- Signal types: 0 – 10 V, 2 – 10 V, 0 – 20 mA, 4 – 20 mA, PT1000
- Applications: Remote adjustment of the setpoints in every control mode (except Multi-Flow Adaptation), sensor inputs for temperature, differential pressure or free sensor in user-defined PID-operating mode
- For potential-free control outputs or switch
- Parametrizable functions:
- Ext. Off
- Ext. Min
- Ext. Max
- MANUAL (BMS-OFF)
- Key lock
- Switchover between heating/cooling mode
Signal and display functions
- Display status operation display:
- Setpoint
- Actual delivery head
- Actual volume flow
- Power consumption
- Electric consumption
- Temperatures
- Status display LED: Faultless operation (green LED), pump communication (blue LED)
- Display status of display fault (display red):
- Error codes and error description in full text
- Remedial measures
- Display status of display warning (display yellow):
- Warning codes and description of the warning in full text
- Remedial measures
- Display status process indicator (display blue):
- Pump venting
- Update procedure
- Display BMS communication (display blue):
- Summary of the active BMS parameters (baud rate, address,...)
- Collective fault signal SSM (potential-free changeover contact)
- Collective run signal SBM (potential-free normally open contact)
- Bluetooth interface for wireless data exchange and remote operation of the pump using a smartphone or tablet.
- Serial digital interface Modbus RTU for connecting building automation (BA) via RS485 bus system (possible with Wilo-CIF module Modbus RTU).
- Serial digital interface BACnet MS/TP for connecting building automation (BA) via RS485 bus system (possible with Wilo-CIF module BACnet MS/TP).
- Serial digital interface LON for connecting building automation (BA) via bus system LONWorks (possible with Wilo-CIF module LON).
- Serial digital interface PLR for connecting BA via company-specific coupling module (possible with Wilo-CIF module PLR).
- Main/standby operation (automatic fault-actuated switchover/time-sensitive pump alteration)
- Parallel operation (efficiency-optimised peak load cut-in and out)
- For flange-end pumps: Flange versions
- Standard version for DN 32 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges
- Standard version for DN 80/DN 100 pumps: PN 6 flange (designed for PN 16 according to EN 1092-2) for PN 6 counter flange
- Special version for DN 32 to DN 100 pumps: PN 16 flange (according to EN 1092-2) for PN 16 counter flange
- Various integrated communication interfaces and optionally usable CIF module plug-in position
- 5 cable inlets for connecting the communication interfaces
- Bluetooth interface
- High resolution graphic display with green button and 2 additional buttons
- User-friendly terminal room
- Integrated temperature sensor
- Thermal insulation as standard for heating applications
- Quick electrical connection with optimised Wilo-Connector for the power supply
- Pump
- Optimised Wilo-Connector
- 2x threaded cable connection M16 x 1.5
- Washers for flange screws (for nominal connection diameters DN 32 - DN 65)
- Gaskets for threaded connection
- Thermal insulation
- Installation and operating instructions
- Permissible temperature range -10 °C to +110 °C
- Mains connection 1~230 V, 50/60 Hz
- Protection class IPX4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar or 6 bar (special version: 10 bar or 16 bar)
- Insulation class: F
- Emitted interference in acc. with: EN 61800-3:2004+A1:2012 / residential environment (C1)
- Interference resistance in acc. with: EN 61800-3:2004+A1:2012 / industrial environment (C2)
- Pump housing: grey cast iron with cataphoretic-coated
- Thermal insulation: polypropylene
- Shaft: Stainless steel
- Bearing: carbon
- Impeller: Plastic
- Smart glandless circulator with EC motor and integrated electronic power adjustment
- Green Button Technology and graphic display
- Motor protection with trip electronics
- Plug connection for functional extension with optional CIF module for building automation (BA)
- Impeller with three-dimensionally curved blades and plastic sealing tube made of carbon fibre composite material
Prefabricated diffusion-proof insulation cover, designed for Wilo-Stratos MAXO pumps. Preferably used in air conditioning and cooling systems. This is to avoid condensation and to minimise energy losses.
- Delivery includes Armaflex tape for sealing between insulation and pump flange.
- Media temperature range -10 ° C to 110 ° C.
- Made of Armaflex material.
- Water vapor from diffusion resistance μ ≥ 10,000.
- Thermal conductivity 0.033 W / (m · K).
- Easy installation- time saving.
- Cost effective total solution.
- Installation of drip tray not necessary.
- Fits all Strato's MAXO pumps.
- Fits all Strato's MAXO pumps.
Connection to Stratos Maxo to detect the fluid temperature in the case of temperature-dependent pump control or to detect heating/cooling quantities.
- Sensor Pt 1000 Class AA, ø6 x 40 mm
- Cable length: 3 m
- Measurement range: -5 °C to 70 °C, briefly up to 90 °C
Connection to Stratos Maxo-Z to detect the hot water outlet temperature on the reservoir to detect the thermal disinfection.
- Sensor Pt 1000 Class B, ø8.5 x 35 mm
- Cable length 5 m
- Measurement range -5 °C to 70 °C, briefly up to 90 °C.
For admission of the immersion sensor Pt 1000 AA for connection to Stratos MAXO.
- Thread: G 1/2
- Inner Ø 6.4 mm for sensor to ø6 mm
- Length of engagement 45 mm for installation in thread T-connector for use with pipes from DN 25 to approx. DN 50
General functions
Serial, digital interface for connection to building automation (BA) for the transfer of data points as:
- Control commands to the pump
- Messages from the pump
- Process values
General functions
Serial, digital interface for connection to building automation (BA) for the transfer of data points as:
- Control commands to the pump
- Messages from the pump
- Process values
General functions:
Serial, digital interface for connection to building automation (BA) for the transfer of data points as:
- Control commands to the pump
- Messages from the pump
- Process values
General functions:
Serial, digital interface for connection to building automation (BA) for the transfer of data points as:
- Control commands to the pump
- Messages from the pump
- Process values
Enables remote monitoring and control of connected products using the Wilo-Smart connect function in the Wilo Assistant app.
General functions
Serial, digital interface for connection to building automation (BA) for the transfer of data points as:
- Control commands to the pump
- Messages from the pump
- Process values
General functions:
Serial, digital interface for connection to building automation (BA) for the transfer of data points as:
- Control commands to the pump
- Messages from the pump
- Process values
Temperature sensor intended for Stratos MAXO -R7 and Stratos MAXO-D -R7 (threaded pumps).
Features:
- Operation via control mode T-const. and ΔT const.
- Night setback
- Measurement of heating and cooling energy
- Automatic switching between heating / cooling
The sensor measures the differential pressure between the suction ports and discharge ports to the pipes, and converts this into an electrical signal 4-20 mA, which is used by the frequency converter to regulate the pressure of the pump. The value of the output current is proportional to the differential pressure.
Replacement pump - High Efficiency Standard Exchange sheet
Comment
Product information
Yonos MAXO 30/0,5-7
Your advantages
- LED display provides complete transparency of set delivery head, speed stage or possible errors
- Simple adjustment over three speed stages when replacing an uncontrolled standard pump
- Easier electrical connection using the Wilo plug
- System availability ensured via collective fault signal
- Compact design and proven ease of use
Glandless circulator with flange connection, EC motor with automatic power adjustment.
Application
Hot-water heating systems of all kinds, air-conditioning systems, closed cooling circuits, industrial circulation systems.
Equipment/function
Operating modes:
- Δp-c for constant differential pressure
- Δp-v for variable differential pressure
- Setting the operating mode
- Setting of pump output (delivery head)
- Infinitely variable power adjustment according to the operating mode
- Deblocking function
- Soft start
- Integrated full motor protection
- Collective fault signal (potential-free NC contact)
- Fault signal light
- LED segment display for displaying the delivery head and fault codes
- Wrench attachment point on pump body (for threaded pipe union pumps)
- Quick electrical connection with Wilo plug. For the connection of the mains and SSM lines, with integrated strain relief
- For flange-end pumps: Flange versions
- Standard version for pumps DN 32 to DN 65: Combination flange PN 6/10 (flange PN 16 acc. to EN 1092-2) for counter flanges PN 6 and PN 16
- Standard version for DN 80/DN 100 pumps: PN 6 flange (designed for PN 16 according to EN 1092-2) for PN 6 counter flange
- Pump
- Incl. washers for flange screws (for nominal connection diameters DN 32 - DN 65)
- Including installation and operating instructions
- Permissible temperature range of -20°C to +110°C
- Mains connection 1~230 V, 50/60 Hz
- Protection class IP X4D
- Flange connection DN 32 to DN 80
- Max. operating pressure of standard version: 6/10 bar or 6 bar (special version: 10 bar)
- Pump housing: grey cast iron with cataphoretic coating
- Shaft: Stainless steel
- Bearing: carbon, metal impregnated
- Impeller: Plastic
- Thermal insulation of pump housing in heating applications.
- Reduces heat loss by up to 85%.
- Energy saving, reduces operating costs.
- Protects the pump from external damage.
- 100% recyclable.
The Wilo-Connect module Yonos MAXO is installed on the electronic module of the pump at the position of the Wilo plug.
Utilisation of the Wilo-Connect moduleYonos MAXO dispenses with external contactors and other switchgears as well as the associated installation workload. The load of customer-side switchgears (relays) due to high starting currents is reduced to a minimum by the Connect module Yonos MAXO.
Equipment/function
- Run signal display
- SSM collective fault signal as potential-free NC contact
- SBM collective run signal as potential-free NO contact
- Overriding Off control input (External Off)
- Integrated dual pump management with the functions:
- Main/standby operation with runtime-dependent (24 h) switchover from main to standby pump
- Fault-sensitive switchover to operational standby pump