2 replacement options found

Existing pump - Circulation Pump curve

Brand Biral
Product name W 403 PN10 3~
Overall length 250 mm
Mains connection 3x400 V
Pipe Connection DN 40 PN10

Replacement pump - High Efficiency Premium Smart Exchange sheet

Product name Stratos MAXO-Z 40/0,5-8
Item no. 2164674
Overall length 220 mm
Mains connection 1x230 V
Pipe Connection DN 40 PN6/10
Rated Current 0,11-1,20 A
Nominal power P2 0,246 kW
Fluid temperature range 0 - +80 °C

Exchange accessories

Intermediate flange F1 DN 40 X 30mm PN10/16-MS
Item no. 2060920
Number 1

Comment

Fits replacement accessories without any modification of piping. **NOTE** 1~.

Product information
Stratos MAXO-Z 40/0,5-8

Stratos MAXO-Z 40/0,5-8
Item no. : 2164674

Your advantages
  • Intuitive operation by means of application-guided settings with the Setup Guide plus the combination of a new display and operating button using Green Button Technology.
  • Highest standard of drinking water hygiene and energy efficiency with the new, innovative, intelligent T-const. control function.
  • Optimum hygiene promotion through thermal disinfection detection.
  • Latest communication interfaces (e.g. Bluetooth) for connection to mobile devices and direct pump networking for multiple pump control via Wilo Net.
  • Maximum convenience in electrical installation thanks to a clearly arranged and spacious terminal room and the optimised Wilo-Connector.
Superior intelligence, unparalleled quality.
The Wilo-Stratos MAXO-Z has specifically been developed for drinking water applications and combines the innovative characteristics of the Wilo-Stratos MAXO with a stainless steel housing. The durable and hygienic material sets it apart from other domestic hot water circulators on the market.

Construction
Smart glandless circulator with screwed connection or flange connection, EC motor with integrated electronic power adjustment.

Application
Domestic hot water circulation systems of all kinds, hot-water heating systems of all kinds, air-conditioning, closed cooling circuits, industrial circulation systems.

Equipment/function
Field of application:

The pump facilitates an operation with highest system efficiency via precise setting of the control mode for the system-specific application (e.g. radiator, underfloor heating, ceiling cooling).

Heating
  • Radiator
  • Underfloor heating
  • Ceiling heating
  • Fan heater
  • Hydraulic shunt
  • Heat exchanger
Cooling
  • Ceiling cooling
  • Underfloor cooling
  • Air-conditioning devices
  • Hydraulic shunt
  • Heat exchanger
Heating and cooling combined
  • Automatic switchover
The following control modes are available depending on the selected application:

Control modes
  • Constant speed (control mode)
  • Δp-c for constant differential pressure
  • Δp-v for variable differential pressure
  • Dynamic Adapt plus for continuous (dynamic) adjustment of the delivery rate to the current requirement
  • T-const. for constant temperature regulation
  • ΔT for differential temperature control
  • Constant Q for constant volume flow control
  • Multi-Flow Adaptation: Total volume flow determination through the feeder pump for the needs-based supply of secondary pumps in the heating circuit distributors
  • User-defined PID controller
Optional functions
  • Q-limitmax. for limiting the maximum volume flow
  • Q-limitmin. for limiting the minimum volume flow
  • No-Flow Stop (zero-flow-deactivation)
  • Automatic setback operation
  • Index circuit evaluator (Δp-c control with external actual value sensor)
  • Thermal disinfection detection
  • Variable pitch of Δp-v pump curve
Manual settings
  • Selection of the field of application using the Setup Guide
  • Setting the related operating parameters
  • Nominal duty point: direct input of calculated duty point at Δp-v
  • Status display
  • Setting and resetting the energy meters (heating and cooling)
  • Pump venting function
  • Key lock for disabling the settings
  • Function for resetting the factory settings or the saved restoration points (parameter sets)
  • Parameterising the analogue inputs
  • Parameterising the binary inputs
  • Parameterising the relay outputs
Automatic functions
  • Power adjustment according to requirements for energy-efficient operation depending on the operating mode
  • Setback operation
  • Deactivation at zero flow (No-Flow Stop)
  • Soft start
  • Automatic troubleshooting routines (e.g. deblocking function)
  • Switchover heating/cooling mode
  • Full motor protection with integrated trip electronics
External control inputs and their functions
2 x analogue inputs:
  • Signal types: 0 – 10 V, 2 – 10 V, 0 – 20 mA, 4 – 20 mA, PT1000
  • Applications: Remote adjustment of the setpoints in every control mode (except Multi-Flow Adaptation), sensor inputs for temperature, differential pressure or free sensor in user-defined PID-operating mode
2 x digital inputs:
  • For potential-free control outputs or switch
  • Parametrizable functions:
  • Ext. Off
  • Ext. Min
  • Ext. Max
  • MANUAL (BMS-OFF)
  • Key lock
  • Switchover between heating/cooling mode
Wilo Net for dual pump management of 2 single pumps, communication of several pumps with each other and pump-remote adjustment via gateway

Signal and display functions
  • Display status operation display:
  • Setpoint
  • Actual delivery head
  • Actual volume flow
  • Power consumption
  • Electric consumption
  • Temperatures
  • Status display LED: Faultless operation (green LED), pump communication (blue LED)
  • Display status of display fault (display red):
  • Error codes and error description in full text
  • Remedial measures
  • Display status of display warning (display yellow):
  • Warning codes and description of the warning in full text
  • Remedial measures
  • Display status process indicator display (display blue):
  • Pump venting
  • Update procedure
  • Display BMS communication (display blue):
  • Summary of the active BMS parameters (baud rate, address,...)
  • Collective fault signal SSM (potential-free changeover contact)
  • Collective run signal SBM (potential-free normally open contact)
Data exchange
  • Bluetooth interface for wireless data exchange and remote operation of the pump using a smartphone or tablet.
  • Serial digital interface Modbus RTU for connecting building automation (BA) via RS485 bus system (possible with Wilo-CIF module Modbus RTU).
  • Serial digital interface BACnet MS/TP for connecting building automation (BA) via RS485 bus system (possible with Wilo-CIF module BACnet MS/TP).
  • Serial digital interface LON for connecting building automation (BA) via bus system LONWorks (possible with Wilo-CIF module LON).
  • Serial digital interface PLR for connecting BA via company-specific coupling module (possible with Wilo-CIF module PLR).
Equipment
  • For flange-end pumps: Flange versions
  • Standard version for DN 32 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges
  • Standard version for DN 80/DN 100 pumps: PN 6 flange (designed for PN 16 according to EN 1092-2) for PN 6 counter flange
  • Special version for DN 32 to DN 100 pumps: PN 16 flange (according to EN 1092-2) for PN 16 counter flange
  • Various integrated communication interfaces and optionally usable CIF module plug-in position
  • 5 cable inlets for connecting the communication interfaces
  • Bluetooth interface
  • High resolution graphic display with green button and 2 additional buttons
  • User-friendly terminal room
  • Integrated temperature sensor
  • Thermal insulation as standard for heating applications
  • Quick electrical connection with optimised Wilo-Connector for the power supply
Scope of delivery
  • Pump
  • Optimised Wilo-Connector
  • 2x threaded cable connection M16 x 1.5
  • Washers for flange screws (for nominal connection diameters DN 32 - DN 65)
  • Including gaskets for threaded connection
  • Thermal insulation
  • Installation and operating instructions
Technical data
  • Permissible temperature range
  • Drinking water up to 3.57 mmol/l (20 °dH): 0 °C to +80 °C
  • Heating water: -10 °C to +110 °C
  • Mains connection 1~230 V, 50/60 Hz
  • Protection class IPX4D
  • Screwed connection or flange connection (depending on type) Rp 1 to DN 65
  • Max. operating pressure of standard version: 6/10 bar (special version: 16 bar)
  • Insulation class: F
  • Emitted interference in acc. with: EN 61800-3:2004+A1:2012 / residential environment (C1)
  • Interference resistance in acc. with: EN 61800-3:2004+A1:2012 / industrial environment (C2)
Materials
  • Pump housing made of stainless steel
  • Thermal insulation: polypropylene
  • Impeller: Plastic
  • Shaft: Stainless steel
  • Bearing: carbon
Description/construction
  • Smart glandless circulator with EC motor and integrated electronic power adjustment
  • Green Button Technology and graphic display
  • Motor protection with trip electronics
  • Plug connection for functional extension with optional CIF module for building automation (BA)
  • Impeller with three-dimensionally curved blades and plastic sealing tube made of carbon fibre composite material
CONNECTOR Stratos MAXO
Item no.: 2194141
Contact, Stratos MAXO:
  • Fits all Strato's MAXO pumps.
CONNECTOR Angle Stratos MAXO
Item no.: 2212505
Contact angle, Stratos MAXO:
  • Fits all Strato's MAXO pumps.
Flange gasket DN 40 PN6/10
Item no.: 2150949
Flange gasket DN 40 PN6 / 10, Klingersil:
  • Thickness: 2 mm.
  • Inner diameter: 49 mm.
  • Outer diameter: 85 mm.
PT 1000 AA Sensor f.heating circulation 3m
Item no.: 2193422

Temperature sensor for installation in immersion sleeve with inside diameter 6.5 mm.
Connection to Stratos Maxo to detect the fluid temperature in the case of temperature-dependent pump control or to detect heating/cooling quantities.
  • Sensor Pt 1000 Class AA, ø6 x 40 mm
  • Cable length: 3 m
  • Measurement range: -5 °C to 70 °C, briefly up to 90 °C
Pipe surface contact sensor Pt 1000 B
Item no.: 2193421

Temperature sensor for attachment to pipes.
Connection to Stratos Maxo-Z to detect the hot water outlet temperature on the reservoir to detect the thermal disinfection.
  • Sensor Pt 1000 Class B, ø8.5 x 35 mm
  • Cable length 5 m
  • Measurement range -5 °C to 70 °C, briefly up to 90 °C.
Immersion well G 1/2", 100mm
Item no.: 2193424

Immersion sleeve with PG 7 clamp bolting and silicone rings.
For admission of the immersion sensor Pt 1000 AA for connection to Stratos MAXO.
  • Thread: G 1/2
  • Inner Ø 6.4 mm for sensor to ø6 mm
  • Length of engagement 100 mm for installation in thread T-connector for use with pipes from approx. DN 65 to DN 100
Immersion well G 1/2", 45mm
Item no.: 2193423

Immersion sleeve with PG 7 clamp bolting and silicone rings.
For admission of the immersion sensor Pt 1000 AA for connection to Stratos MAXO.
  • Thread: G 1/2
  • Inner Ø 6.4 mm for sensor to ø6 mm
  • Length of engagement 45 mm for installation in thread T-connector for use with pipes from DN 25 to approx. DN 50
CIF-Module BACnet
Item no.: 2190367

Interface modules as retrofittable plug-in modules for extending the communication interfaces of the pump in accordance with various standards and protocol variants according to type key.

General functions
Serial, digital interface for connection to building automation (BA) for the transfer of data points as:
  • Control commands to the pump
  • Messages from the pump
  • Process values
CIF-Module CAN
Item no.: 2190369

Interface modules as retrofittable plug-in modules for extending the communication interfaces of the pump in accordance with various standards and protocol variants according to type key.

General functions
Serial, digital interface for connection to building automation (BA) for the transfer of data points as:
  • Control commands to the pump
  • Messages from the pump
  • Process values
CIF-Module LON
Item no.: 2190370

Interface modules as retrofittable plug-in modules for extending the communication interfaces of the pump in accordance with various standards and protocol variants according to type key.

General functions:
Serial, digital interface for connection to building automation (BA) for the transfer of data points as:
  • Control commands to the pump
  • Messages from the pump
  • Process values
CIF-Module Modbus
Item no.: 2190368

Interface modules as retrofittable plug-in modules for extending the communication interfaces of the pump in accordance with various standards and protocol variants according to type key.

General functions:
Serial, digital interface for connection to building automation (BA) for the transfer of data points as:
  • Control commands to the pump
  • Messages from the pump
  • Process values
Smart Gateway
Item no.: 2197100

REG device to establish communication between Wilo products with Wilo Net and the Wilo-Smart Cloud via Internet.
Enables remote monitoring and control of connected products using the Wilo-Smart connect function in the Wilo Assistant app.
CIF-Module Ethernet
Item no.: 2211408

Interface modules as retrofittable plug-in modules for extending the communication interfaces of the pump in accordance with various standards and protocol variants according to type key.

General functions
Serial, digital interface for connection to building automation (BA) for the transfer of data points as:
  • Control commands to the pump
  • Messages from the pump
  • Process values
CIF-Modul Modbus TCP
Item no.: 2211409

Interface modules as retrofittable plug-in modules for extending the communication interfaces of the pump in accordance with various standards and protocol variants according to type key.

General functions:
Serial, digital interface for connection to building automation (BA) for the transfer of data points as:
  • Control commands to the pump
  • Messages from the pump
  • Process values
Difference pressure sensor 10 m
Item no.: 2136454

The differential pressure sensor kit enables dp-c and dp-v control of the frequency-controlled high-pressure centrifugal pumps.
The sensor measures the differential pressure between the suction ports and discharge ports to the pipes, and converts this into an electrical signal 4-20 mA, which is used by the frequency converter to regulate the pressure of the pump. The value of the output current is proportional to the differential pressure.

Replacement pump - Conventional Exchange sheet

Product name TOP-Z 40/7 3~
Item no. 2175516
Overall length 250 mm
Mains connection 3x400 V
Pipe Connection DN 40 PN6/10
Rated Current 0,32/0,44/0,70 A
Nominal power P2 0,18 kW
Fluid temperature range Max +80 °C

Comment

Fits without any modification of piping.

Product information
TOP-Z 40/7 3~

TOP-Z 40/7 3~
Item no. : 2175516

Your advantages
  • Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~)
  • With thermal insulation as standard
Construction
Glandless circulator with screwed connection or flange connection. Pre-selectable speed stages for power adjustment.

Application
Domestic hot water circulation systems in industry and building services.

Equipment/function
Operating modes:
  • Speed-stage switching
Manual functions
  • Setting the speed stages: 3 speed stages
Automatic functions
  • Internal protection against unacceptably high winding temperatures (only for pumps with P2 < 180 W, optional for all types with switchgears SK 602N and SK 622N).
Signal and display functions
  • Thermal winding contact (WSK, potential-free NC contact) (only for pumps with P2 ≥ 180 W)
  • Direction of rotation signal lamp (only for 3~ pumps)
Equipment
  • For flange-end pumps: Flange versions
  • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
  • Standard version for pumps DN 80: PN 6 flange (designed for PN 16 according to EN 1092-2) for PN 6 counter flange
  • Special version for DN 40 to DN 80 pumps: PN 16 flange (according to EN 1092-2) for PN 16 counter flange,
  • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2≥180 W)
  • Thermal insulation as standard
Scope of delivery
  • Pump
  • Including thermal insulation
  • Including gaskets for threaded connection
  • Including washers for flange screws (for nominal connection diameters DN 40 - DN 65)
  • Including installation and operating instructions
Technical data
  • Permissible temperature range
  • TOP-Z 20/4 and TOP-Z 25/6 drinking water up to 3.21 mmol/l (18 °dH): max. +65 °C, in short-term operation (2 h) up to +80 °C
  • From TOP-Z 25/10 drinking water up to 3.57 mmol/l (20 °dH): max. +80 °C, in short-term operation (2 h) up to +110 °C
  • Mains connection:
  • 1~230 V, 50 Hz (depending on type)
  • 3~230 V, 50 Hz (with optional switching plug)
  • 3~400 V, 50 Hz
  • Protection class IP X4D
  • Screwed connection or flange connection (depending on type) Rp ¾ to DN 80
  • Max. operating pressure of standard version: 6/10 bar or 6 bar (special version: 10 bar or 16 bar)
Materials
  • Pump housing: Stainless steel/red brass/grey cast iron (depending on type)
  • Impeller: Plastic
  • Shaft: Stainless steel/ceramic (depending on type)
  • Bearing: Carbon, synthetic resin impregnated