Existing pump - Circulation
Replacement pump - High Efficiency Premium Exchange sheet
Comment
Product information
Stratos PICO-Z 25/0,5-6 -180
Design
Glandless circulator with screwed connection, blocking-current proof EC motor and integrated electronic power control.
Application
Domestic hot water circulation systems in the industry and building services.
Equipment/function
Operating modes:
- T-const. for temperature-controlled mode
- Δ p-c for constant differential pressure
- Constant speed (n-const.)
- Setting the operating mode
- Setting of pump output (delivery head)
- Setting the minimum temperature
- Setting the minimum flow rate
- Pump venting
- Manual restart
- Reset function for resetting the electricity meter
- Reset function for resetting to factory settings
- Key lock for disabling the settings
- Continuous power adjustment according to the operating mode
- Temperature control for maintaining a constant return temperature in the domestic hot water circulation system
- Thermal disinfection routine (detecting and supporting the thermal disinfection of the domestic hot water storage tank)
- Automatic venting function
- Automatic restart
Alternating display:
- Current volume flow [m³/h]
- Current delivery head H in [m]
- Current speed (n) [rpm]
- Power consumption P [W]
- Energy consumption W [kWh]
-
Current temperature T [°C]
- Display status for warning messages (yellow display) and error messages (red display) each with error code and description in plain text
- Display status for process display (blue display):
- Pump venting
- Manual restart
- Status LED:
- Green LED: Proper operation
- Blue LED: Pump communication with external module
- Wrench attachment point on pump body
- Quick electrical connection with Wilo-Connector
- Blocking-current proof motor
- Particle filter
- Thermal insulation as standard
- Wilo-Connectivity interface for external modules
- Fluid temperature +2 °C to +95 °C
- Mains connection 1~230 V, 50 Hz
- Protection class IPX4D
- Screwed connection G1¼, G1½, G2
- Max. operating pressure 10 bar
- Pump housing: Stainless steel
- Thermal insulation: Polypropylene
- Impeller: Plastic
- Shaft: Oxide ceramic
- Bearing: Carbon, synthetic resin-impregnated
- Pump
- Thermal insulation
- Wilo-Connector
- Gaskets
- Installation and operating instructions
- Made of brass/
- Union couplings are delivered complete (in pairs) in a bag with a gasket.
- Fits PICO pumps and Star-Z NOVA.
- Fits PICO pumps and Star-Z NOVA.
- Comes with cable.
- WS8 connector.
- Cable length 2 meters.
interface for building management systems (BMS).
The module is mounted on the electronic module via the Wilo-Connectivity interface of the pump
Equipment/function
- Run signal display
- Analogue input 0 -10 V for setpoint specification
- Run signal display via relay output as changeover contact
- SSM collective fault signal as potential-free NC contact
- SBM collective run signal as potential-free NO contact
-
Control input with configurable functions:
- Override OFF (External OFF), MIN (External MIN), MAX (External MAX)
- 2 PG screwed connections, rotatable with vertical or horizontal orientation
Replacement pump - High Efficiency Standard Exchange sheet
Comment
Product information
Yonos PICO-Z 25/0,5-6 -180
Design
Glandless circulator with screwed connection, blocking-current proof EC motor and integrated electronic power control.
Application
Domestic hot water circulation systems in the industry and building services.
Equipment/function
Operating modes:
- Δ p-c for constant differential pressure
- Constant speed (3 constant speed stages)
- Constant speed (continuously adjustable)
- Setting the operating mode
- Setting of pump output (delivery head)
- Setting the constant speed (continuous or fixed)
- Pump venting function
- Manual restart
- Continuous power adjustment according to the operating mode
- Automatic restart
- Automatic dry-running detection
- Display of the current power consumption in W
- Display of the current flow in m³/h
- Delivery head in m
- Constant speed (c1, c2; c3)
- Speed during continuous adjustment (n/100)
- Display of fault messages (error codes)
- Display of manually activated restart or pump venting function
- Wrench attachment point on pump body
- Quick electrical connection with Wilo-Connector
- Blocking-current proof motor
- Particle filter
- Thermal insulation as standard
- Fluid temperature +2 °C to +95 °C
- Mains connection 1~230 V, 50 Hz
- Protection class IPX4D
- Screwed connection G1, G1½, G1¼
- Max. operating pressure 10 bar
- Pump housing: Stainless steel
- Impeller: Plastic
- Shaft: Oxide ceramic
- Bearing: Carbon, synthetic resin-impregnated
- Pump
- Thermal insulation
- Wilo-Connector
- Gaskets
- Installation and operating instructions
- Made of brass/
- Union couplings are delivered complete (in pairs) in a bag with a gasket.
- Fits PICO pumps and Star-Z NOVA.
- Fits PICO pumps and Star-Z NOVA.
- Comes with cable.
- WS8 connector.
- Cable length 2 meters.
Replacement pump - Conventional Exchange sheet
Comment
Product information
IP-Z 25/2 1~
Your advantages
- High resistance to corrosive fluids due to stainless steel housing and Noryl impeller
- Wide range of applications due to suitability for water hardness up to 5 mmol/l (28 °dH)
- All plastic parts that come into contact with the fluid fulfil KTW recommendations
Glanded circulator in in-line design with screwed connection.
Top suction inlet. A special version (-N0) is required for a downward suction inlet.
Application
For pumping drinking water, cold and hot water (in accordance with VDI 2035) without abrasive substances, in heating, cold water and cooling water systems.
Scope of delivery
- Pump
- Installation and operating instructions
- Permissible ambient temperature range: -15 °C to 40 °C
- Drinking water up to 5 mmol/l (28 °dH): max. +65 °C, in short-time duty (2 h) up to +110 °C
- Heating water: -8 °C to +110 °C
- Mains connection 1~230 V, 50 Hz or 3~230/400 V, 50 Hz
- Protection class IP54
- Nominal diameter Rp 1
- Max. operating pressure 10 bar
- Pump housing and lantern: 1.4306
- Impeller: Noryl
- Shaft: 1.4571
- Mechanical seal: Ceramic/graphite/EPDM
Single-stage, low-pressure centrifugal pump in in-line design with:
- Mechanical seal
- Screwed connection
- Motor with one-piece shaft
Automatic reactivation of pump after power failure and automatic fault acknowledgement after cooling off of the motor.
Equipment/function:
- Full motor protection tripping unit for pumps with thermal winding contact (WSK)
- Switch on/off with integrated run signal light
- Terminals for external, potential-free activation/deactivation
- Connection terminal strip