1 replacement option found

Existing pump - Circulation

Brand KSB
Product name Z 65-150 D Rio
Overall length 340 mm
Mains connection 3x400 V
Pipe Connection DN 65 PN6/10

Replacement pump - High Efficiency Standard Exchange sheet

Product name Yonos MAXO-D 65/0,5-16
Item no. 2120671
EEI ≤ 0,23
Overall length 340 mm
Mains connection 1x230 V
Pipe Connection DN 65 PN6/10
Fluid temperature range -20 - +110 °C

Comment

One Connect-Module would be required per pump head.
Fits without any modification of piping. **NOTE** 1~.
This Pump is equipped with alarm output (SSM) as standard. Additonal functions (external on/off, external operation indication) can be added with the simple install of the Connect-Module.

Product information
Yonos MAXO-D 65/0,5-16

Yonos MAXO-D 65/0,5-16
Item no. : 2120671

Your advantages
  • LED display provides complete transparency of set delivery head, speed stage or possible errors
  • Simple adjustment over three speed stages when replacing an uncontrolled standard pump
  • Easier electrical connection using the Wilo plug
  • System availability ensured via collective fault signal
  • Compact design and proven ease of use
Construction
Glandless circulator with flange connection, EC motor with automatic power adjustment.

Application
Hot-water heating systems of all kinds, air-conditioning systems, closed cooling circuits, industrial circulation systems.

Equipment/function
Operating modes:
  • Δp-c for constant differential pressure
  • Δp-v for variable differential pressure
Manual functions
  • Setting the operating mode
  • Setting of pump output (delivery head)
Automatic functions
  • Infinitely variable power adjustment according to the operating mode
  • Deblocking function
  • Soft start
  • Integrated full motor protection
Signal and display functions
  • Collective fault signal (potential-free NC contact)
  • Fault signal light
  • LED segment display for displaying the delivery head and fault codes
Twin-head pump function
  • Main/standby operation: for an automatic fault-actuated switchover, a corresponding switchgear must be provided on-site
  • Predefined control mode and set delivery head must be identical for both pumps 
Equipment
  • Wrench attachment point on pump body (for threaded pipe union pumps)
  • Quick electrical connection with Wilo plug. For the connection of the mains and SSM lines, with integrated strain relief
  • For flange-end pumps: Flange versions
  • Standard version for pumps DN 32 to DN 65: Combination flange PN 6/10 (flange PN 16 acc. to EN 1092-2) for counter flanges PN 6 and PN 16
  • Standard version for DN 80/DN 100 pumps: PN 6 flange (designed for PN 16 according to EN 1092-2) for PN 6 counter flange
Scope of delivery
  • Pump
  • Incl. washers for flange screws (for nominal connection diameters DN 32 - DN 65)
  • Including installation and operating instructions
Technical data
  • Permissible temperature range of -20°C to +110°C
  • Mains connection 1~230 V, 50/60 Hz
  • Protection class IP X4D
  • Flange connection DN 32 to DN 80
  • Max. operating pressure of standard version: 6/10 bar or 6 bar (special version: 10 bar)
Materials
  • Pump housing: grey cast iron with cataphoretic coating
  • Shaft: Stainless steel
  • Bearing: carbon, metal impregnated
  • Impeller: Plastic
COUNTER FLANGE KIT DN65 PN10
Item no.: 2105583
Mating flanges:
  • Made of steel.
  • Counter flanges (weld) are delivered complete (in pairs) with bolt, nut and flange gasket.
BLANK FLANGE GR.53/63 KIT
Item no.: 2049279
Blinds for service and repair work.
  • Comes in a complete kit containing a lid and gasket.
Flange gasket DN 65 PN6/10
Item no.: 2151002
Flange gasket DN 65 PN6 / 10, Klingersil:
  • Thickness: 2 mm.
  • Inner diameter: 77 mm.
  • Outer diameter: 115 mm.
Connect-Module Yonos MAXO
Item no.: 2210108

The Wilo-Connect module Yonos MAXO is a retrofittable plug-in module for Wilo-Yonos MAXO/Yonos MAXO-D/Yonos MAXO-Z pumps.
The Wilo-Connect module Yonos MAXO is installed on the electronic module of the pump at the position of the Wilo plug.

Utilisation of the Wilo-Connect moduleYonos MAXO dispenses with external contactors and other switchgears as well as the associated installation workload. The load of customer-side switchgears (relays) due to high starting currents is reduced to a minimum by the Connect module Yonos MAXO.

Equipment/function
  • Run signal display
  • SSM collective fault signal as potential-free NC contact
  • SBM collective run signal as potential-free NO contact
  • Overriding Off control input (External Off)
  • Integrated dual pump management with the functions:
  • Main/standby operation with runtime-dependent (24 h) switchover from main to standby pump
  • Fault-sensitive switchover to operational standby pump