1 replacement option found

Existing pump - Drainage and sewage

Brand KSB
Product name Amarex KRT S 40-252/225 2 UN G-D
Mains connection 3x400 V
Pipe Connection DN 80
Nominal power P2 9,0 kW

Replacement pump Exchange sheet

Product name Rexa PRO-S04-224A/20T105X540/O
Item no. 6097402
Mains connection 3x400 V
Pipe Connection DN 40/50
Nominal power P2 10,5 kW
Fluid temperature range +3 - +40 °C

Comment

Possible modification of installation, replacement pump has compliant connection diameter.

Product information
Rexa PRO-S04-224A/20T105X540/O

Rexa PRO-S04-224A/20T105X540/O
Item no. : 6097402

FLANGE DN50/RP2" STZN KPL.
Item no.: 4027333
Counterflange:
  • Made of cast iron.
  • Comes complete with flange, bolts and nuts, as well as gaskets.
chainkit PCS 400KG 1.4401 5M CE neutral
Item no.: 6063136
Chain:
  • Maximum pump weight 400kg.
  • Made of acid-resistant steel (1.4401).
  • Length 5 meters.
Liftingchainkit PCS 200KG 1.4401 1M LU neutral
Item no.: 6084895
Chain:
  • Maximum pump weight 200 kg.
  • Made of stainless steel.
  • Length 1 meter.
Liftingchainkit PCS 200KG 1.4401 3M LU neutral
Item no.: 6084894
Chain:
  • Maximum pump weight 200 kg.
  • Made of stainless steel.
  • Length 3 meters.
Liftingchainkit PCS 200KG 1.4401 5M LU neutral
Item no.: 6084893
Chain:
  • Maximum pump weight 200 kg.
  • Made of stainless steel.
  • Length 5 meters.
BEND GD.90 DN40-G1½
Item no.: 2057401
Elbow:
  • Intended for pumps in the Rexa series.
  • 90 degrees.
NON-RETURN-DEVICE DN50 PN10 Z GG25 CPL.
Item no.: 2017166
Check Valve:
  • Intended for pumps in the Rexa series.
  • Connection DN 50 PN10.
GATE VALVE DN50 PN10 GG25 CPL.
Item no.: 2017160
Stop Valve:
  • Intended for pumps in the Rexa series.
  • Connection DN 50 PN10.
Pump foot DN40 KIT
Item no.: 6069669
Bottom foot Rexa CUT
  • Intended for Rexa CUT
DRAIN ALARM
Item no.: 2545133

Network-independent alarm switchgear (self-charging power supply unit) for wall fixation with optical and acoustic alarm signal. 
LEVEL SENSOR 0-1MWS, 10M CABLE
Item no.: 2519924

Level sensor with ATEX approval for level control in sewage water containing faeces. A level sensor is used here to measure the hydrostatic pressure in the medium and to convert it directly in the pressure transducer into an electrical signal by means of a diaphragm. The signal is transmitted to the switchgear and evaluated accordingly.
LEVEL SENSOR 0-2,5mWS, 10m CABLE
Item no.: 2519921

Level sensor with ATEX approval for level control in sewage water containing faeces. A level sensor is used here to measure the hydrostatic pressure in the medium and to convert it directly in the pressure transducer into an electrical signal by means of a diaphragm. The signal is transmitted to the switchgear and evaluated accordingly.
LEVEL SENSOR 0-2,5mWS, 30m CABLE
Item no.: 2519922

Level sensor with ATEX approval for level control in sewage water containing faeces. A level sensor is used here to measure the hydrostatic pressure in the medium and to convert it directly in the pressure transducer into an electrical signal by means of a diaphragm. The signal is transmitted to the switchgear and evaluated accordingly.
LEVEL SENSOR 0-2,5mWS, 50m CABLE
Item no.: 2519923

Level sensor with ATEX approval for level control in sewage water containing faeces. A level sensor is used here to measure the hydrostatic pressure in the medium and to convert it directly in the pressure transducer into an electrical signal by means of a diaphragm. The signal is transmitted to the switchgear and evaluated accordingly.
FLOAT SWITCH WA 65 (PSN-O) 5M
Item no.: 503211390

As a signal transmitter for the system switching, depending on the level of an open container or a cistern.
Switching points: up ON / down OFF
FLOAT SWITCH WA 65 (PSN-O) 10M +VP
Item no.: 503211893

As a signal transmitter for the system switching, depending on the level of an open container or a cistern.
Switching points: up ON / down OFF
FLOAT SWITCH MS 1
Item no.: 2004593

Float switches for level control devices as min./max switches for fluids that are aggressive or contain faeces, floats with the fluid and switches when tilted. Because of its construction and switching point, the float switch can exhibit only a very small hysteresis. This property cannot be changed, not even the length of the cable. In order to use the float switch, a switchgear with adjustable run-on time must be used. Switching: up "ON"/down "OFF"
Float switch WA KR1 S
Item no.: 6082807

As a signal transmitter for the system switching, depending on the level of an open container or a cistern.
Switching points: up ON / down OFF