1 replacement option found

Existing pump - Drainage and sewage

Brand Grundfos
Product name AP50.50.11.1
Mains connection 1x230 V
Pipe Connection G 50 inv.

Replacement pump Exchange sheet

Product name Rexa FIT V05-126 -P 1~
Item no. 6064586
Mains connection 1x230 V
Pipe Connection DN 50
Rated Current 8,8 A
Nominal power P2 1,5 kW
Fluid temperature range +3 - +40 °C
Free ball passage 50

Comment

Possible modification of installation, replacement pump has compliant connection diameter.

Product information
Rexa FIT V05-126 -P 1~

Rexa FIT V05-126 -P 1~
Item no. : 6064586

Your advantages
  • Ready-to-plug and immediately ready to go (A and P version)
  • Attached float switch (A-model) enables easy operation
  • Safe vortex hydraulics with large, free ball passage to prevent clogging during operation
  • Sealing chamber with optional external monitoring
  • Lightweight
Construction
Submersible sewage pump for intermittent operation for stationary and portable wet well installation.

Application
Pumping of:
  • Sewage containing faeces in accordance with EN 12050-1
  • Wastewater
Equipment/function
  • Winding temperature monitoring with bimetal strip
  • Optional external pencil electrode for sealing chamber control
Scope of delivery
  • Submersible sewage pump with 10 m cable
  • Cable version depending on the variant:
  • With bare cable ends (O)
  • With plug (P)
  • With float switch and plug (A)
  • Operating and maintenance manual
Technical data
  • Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Submerged operating mode: S1
  • Non-immersed operating mode: S2-15 min; S3 10%
  • Protection class: IP68
  • Insulation class: F
  • Fluid temperature: 3 – 40 °C, max. 60 °C for 3 min
  • Free passage: 50 / 65 / 80 mm
  • Cable length: 10 m
Materials
  • Motor housing: 1.4301
  • Hydraulics housing: EN-GJL 250
  • Impeller: EN-GJL 250
  • Static gaskets: NBR
  • Sealing on pump side: SiC/SiC
  • Sealing on motor side: C/MgSiO4
  • Shaft end: Stainless steel 1.4021
Description/construction
Submersible sewage pump as submersible monobloc unit for stationary and portable wet well installation in intermittent operation.

Hydraulics
The outlet on the pressure side is designed as horizontal flange connection. The maximum possible dry matter is 8 % (depending on the hydraulics). Vortex impellers are used as the impeller shape.

Motor
The motors available are surface-cooled motors in single-phase version (with built-in operating capacitor) and three-phase version for the direct starting. The waste heat is given off directly to the surrounding fluid via the motor housing. These motors can operated immersed in continuous duty (S1) and non-immersed in short-time duty (S2) or intermittent periodic duty (S3).

Furthermore the motors are equipped with thermal motor monitoring. This protects the motor windings against overheating. For units with single-phase AC motors this is built-in and switches automatically. I.e. if the motor is switched off due to overheating and then cools down it is automatically switched on again. Bimetallic strips are used for this as standard.

In addition the motor can be equipped with an external sealing chamber electrode for monitoring the oil barrier chamber. This signals if there is water ingress into the oil barrier chamber through the mechanical seal on the fluid side.

The connection cable has a length of 10 m as standard and is available in following versions:
  • With bare cable ends
  • With plug
  • With float switch and plug
Seal
There is a sealing chamber between the motor and hydraulics. This is filled with medicinal white oil. The fluid-side and motor-side seals are provided by two mechanical seals which rotate independently of each other.
FLANGE DN50/RP2" STZN KPL.
Item no.: 4027333
Counterflange:
  • Made of cast iron.
  • Comes complete with flange, bolts and nuts, as well as gaskets.
chainkit PCS 400KG 1.4401 5M CE neutral
Item no.: 6063136
Chain:
  • Maximum pump weight 400kg.
  • Made of acid-resistant steel (1.4401).
  • Length 5 meters.
PIPE BOW R2/G2 I./A.STZN
Item no.: 4027332
Elbow:
  • Intended for pumps in the Rexa series.
  • 90 degrees.
HOSE CONNECTION R2"A.INCL.SCHELLE
Item no.: 4027334
Hose fitting:
  • Intended for submersible pumps. Includes hose clamp.
NON-RETURN-DEVICE DN50 PN10 Z GG25 CPL.
Item no.: 2017166
Check Valve:
  • Intended for pumps in the Rexa series.
  • Connection DN 50 PN10.
GATE VALVE DN50 PN10 GG25 CPL.
Item no.: 2017160
Stop Valve:
  • Intended for pumps in the Rexa series.
  • Connection DN 50 PN10.
PRESSURE HOSE ID.60 PN6 SYN.10M CPL.
Item no.: 2018106
Pressure Hose:
Intended for submersible pumps.
  • 10 m.
  • ø60 mm.
  • Max pressure 6 bar.
Pump foot DN50/65 KIT
Item no.: 6064666
Bottom foot Rexa:
  • Intended for Rexa pumps with connection DN 50/65.
Wilo-Control MS-Lift 1x4
Item no.: 2539741

Microprocessor-controlled switchgear for level-dependent control of a submersible pump with float switch for level measurement. The parametrization is carried out using dip switches and potentiometers.
Wilo-Control MS-Lift 2x4
Item no.: 2539745

Microprocessor-controlled switchgear for level-dependent control of a submersible pump with float switch for level measurement. The parametrization is carried out using dip switches and potentiometers.
Wilo-Control EC-Lift 1x12
Item no.: 2543210

Microcontroller-controlled switchgear for level-dependent control of a submersible pump with analogue or digital signal transmitters. Individual parameters are entered via symbol-based menu navigation and an operating button.
Wilo-Control EC-Lift 2x12
Item no.: 2543220

Microcontroller-controlled switchgear for level-dependent control of a submersible pump with analogue or digital signal transmitters. Individual parameters are entered via symbol-based menu navigation and an operating button.
DRAIN ALARM
Item no.: 2545133

Network-independent alarm switchgear (self-charging power supply unit) for wall fixation with optical and acoustic alarm signal. 
LEVEL SENSOR 0-1MWS, 10M CABLE
Item no.: 2519924

Level sensor with ATEX approval for level control in sewage water containing faeces. A level sensor is used here to measure the hydrostatic pressure in the medium and to convert it directly in the pressure transducer into an electrical signal by means of a diaphragm. The signal is transmitted to the switchgear and evaluated accordingly.
LEVEL SENSOR 0-2,5mWS, 10m CABLE
Item no.: 2519921

Level sensor with ATEX approval for level control in sewage water containing faeces. A level sensor is used here to measure the hydrostatic pressure in the medium and to convert it directly in the pressure transducer into an electrical signal by means of a diaphragm. The signal is transmitted to the switchgear and evaluated accordingly.
FLOAT SWITCH WA 65 (PSN-O) 5M
Item no.: 503211390

As a signal transmitter for the system switching, depending on the level of an open container or a cistern.
Switching points: up ON / down OFF
FLOAT SWITCH WA 65 (PSN-O) 10M +VP
Item no.: 503211893

As a signal transmitter for the system switching, depending on the level of an open container or a cistern.
Switching points: up ON / down OFF
FLOAT SWITCH MS 1
Item no.: 2004593

Float switches for level control devices as min./max switches for fluids that are aggressive or contain faeces, floats with the fluid and switches when tilted. Because of its construction and switching point, the float switch can exhibit only a very small hysteresis. This property cannot be changed, not even the length of the cable. In order to use the float switch, a switchgear with adjustable run-on time must be used. Switching: up "ON"/down "OFF"
Float switch WA KR1 S
Item no.: 6082807

As a signal transmitter for the system switching, depending on the level of an open container or a cistern.
Switching points: up ON / down OFF