1 replacement option found

Existing pump - Drainage and sewage

Brand Flygt, ITT, Lowara, Xylem
Product name DX 50-15
Mains connection 3x400 V
Pipe Connection G 50
Nominal power P2 1,5 kW

Replacement pump Exchange sheet

Product name Rexa UNI V06/T15-540
Item no. 6082143
Mains connection 3x400 V
Pipe Connection DN 65/50
Rated Current 3,6 A
Nominal power P2 1,5 kW
Fluid temperature range +3 - +40 °C
Free ball passage 44

Comment

Possible modification of installation, replacement pump has deviating connection diameter.

Product information
Rexa UNI V06/T15-540

Rexa UNI V06/T15-540
Item no. : 6082143

Your advantages
  • Excellent reliability due to corrosion-free hydraulics for universal application and various fluids
  • Easy installation thanks to its light weight, integrated capacitor at the single-phase motor and flange with integrated fixation
  • Optimum efficiency and operational safety thanks to its vortex hydraulics and smooth surfaces
  • Quick maintenance facilitated by direct access to the sealing chamber and pump housing
  • Long maintenance interval thanks to its double seal and a high volume sealing chamber
Construction
Submersible sewage pump for intermittent operation for stationary and portable wet well installation. 

Application
Pumping of:
  • Sewage containing faeces in accordance with EN 12050-1
  • Wastewater
  • Fluids with a pH value of > 4.5
  • Material version "B": Aggressive fluids, e.g. lake/sea water, condensate, distilled water
Equipment/function
  • Winding temperature monitoring with bimetallic strip
Scope of delivery
  • Submersible sewage pump with 10 m cable
  • Operating and maintenance manual
Technical data
  • Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Submerged operating mode: S1
  • Non-immersed operating mode: S2-15 min; S3 10%
  • Protection class: IP68
  • Insulation class: F
  • Fluid temperature: 3 – 40 °C, max. 60 °C for 3 min
  • Free passage: 44 mm
  • Cable length: 10 m
Materials
  • Motor housing: 1.4301
  • Hydraulics housing: PP-GF30 (copolymer)
  • Impeller: PP-GF30 (copolymer)
  • Static gaskets: NBR
  • Sealing on pump side: SiC/SiC
  • Sealing on motor side: NBR (V05), C/MgSiO4 (V06)
  • Shaft end: Stainless steel 1.4401
In material version "B", all parts that come in contact with the fluid are made of stainless steel 1.4401 (AISI 316).

Description/construction
Submersible sewage pump as submersible monobloc unit for stationary and portable wet well installation.

Hydraulics
The outlet on the pressure side is designed as horizontal flange connection. The maximum possible dry matter is 8 %. Vortex impellers are used as the impeller shape. A pump support foot is integrated into the hydraulics housing.

Motor
The motors available are surface-cooled motors in single-phase version (with built-in operating capacitor) and three-phase version for the direct starting. The waste heat is given off directly to the surrounding fluid via the motor housing. These motors can operated immersed in continuous duty (S1) and non-immersed in short-time duty (S2) or intermittent periodic duty (S3).

Furthermore the motors are equipped with thermal motor monitoring. This protects the motor windings against overheating. For units with single-phase AC motors this is built-in and switches automatically. I.e. if the motor is switched off due to overheating and then cools down it is automatically switched on again. Bimetallic strips are used for this as standard.

The connection cable has a length of 10 m as standard and is available in following versions:
  • With bare cable ends
  • With plug
  • With float switch and plug
Seal
There is a sealing chamber between the motor and hydraulics. This is filled with medicinal white oil. The seal on the fluid side is provided by a mechanical seal.
MATING FLANGE DN65-2"½-STZN
Item no.: 4015204
Counterflange:
  • Made of cast iron.
  • Comes complete with flange, bolts and nuts, as well as gaskets.
chainkit PCS 400KG 1.4401 5M CE neutral
Item no.: 6063136
Chain:
  • Maximum pump weight 400kg.
  • Made of acid-resistant steel (1.4401).
  • Length 5 meters.
suspension device DN65/2RK SB
Item no.: 6070150
Coupling:
  • Intended for pumps in the Rexa series.
  • Connection DN 65 / 2RK.
KIT DISCHARGE DN65
Item no.: 4027346
Elbow:
  • Hose DN 65/70 (PVC).
  • 90 degrees.
NON-RETURN-DEVICE DN65 PN10 Z GG25 CPL.
Item no.: 2017167
Check Valve:
  • Intended for pumps in the Rexa series.
  • Connection DN 65 PN10.
GATE VALVE DN65 PN10 GG25 CPL.
Item no.: 2017161
Stop Valve:
  • Intended for pumps in the Rexa series.
  • Connection DN 65 PN10.
Wilo-Control MS-Lift 1x4
Item no.: 2539741

Microprocessor-controlled switchgear for level-dependent control of a submersible pump with float switch for level measurement. The parametrization is carried out using dip switches and potentiometers.
Wilo-Control MS-Lift 2x4
Item no.: 2539745

Microprocessor-controlled switchgear for level-dependent control of a submersible pump with float switch for level measurement. The parametrization is carried out using dip switches and potentiometers.
Wilo-Control EC-Lift 1x12
Item no.: 2543210

Microcontroller-controlled switchgear for level-dependent control of a submersible pump with analogue or digital signal transmitters. Individual parameters are entered via symbol-based menu navigation and an operating button.
Wilo-Control EC-Lift 2x12
Item no.: 2543220

Microcontroller-controlled switchgear for level-dependent control of a submersible pump with analogue or digital signal transmitters. Individual parameters are entered via symbol-based menu navigation and an operating button.
DRAIN ALARM
Item no.: 2545133

Network-independent alarm switchgear (self-charging power supply unit) for wall fixation with optical and acoustic alarm signal. 
LEVEL SENSOR 0-1MWS, 10M CABLE
Item no.: 2519924

Level sensor with ATEX approval for level control in sewage water containing faeces. A level sensor is used here to measure the hydrostatic pressure in the medium and to convert it directly in the pressure transducer into an electrical signal by means of a diaphragm. The signal is transmitted to the switchgear and evaluated accordingly.
LEVEL SENSOR 0-2,5mWS, 10m CABLE
Item no.: 2519921

Level sensor with ATEX approval for level control in sewage water containing faeces. A level sensor is used here to measure the hydrostatic pressure in the medium and to convert it directly in the pressure transducer into an electrical signal by means of a diaphragm. The signal is transmitted to the switchgear and evaluated accordingly.
FLOAT SWITCH WA 65 (PSN-O) 5M
Item no.: 503211390

As a signal transmitter for the system switching, depending on the level of an open container or a cistern.
Switching points: up ON / down OFF
FLOAT SWITCH WA 65 (PSN-O) 10M +VP
Item no.: 503211893

As a signal transmitter for the system switching, depending on the level of an open container or a cistern.
Switching points: up ON / down OFF
FLOAT SWITCH MS 1
Item no.: 2004593

Float switches for level control devices as min./max switches for fluids that are aggressive or contain faeces, floats with the fluid and switches when tilted. Because of its construction and switching point, the float switch can exhibit only a very small hysteresis. This property cannot be changed, not even the length of the cable. In order to use the float switch, a switchgear with adjustable run-on time must be used. Switching: up "ON"/down "OFF"
Float switch WA KR1 S
Item no.: 6082807

As a signal transmitter for the system switching, depending on the level of an open container or a cistern.
Switching points: up ON / down OFF